KEMPEROL 2K-PUR is a two-component, UV-stable high performance seamless and self-terminating cold fluid-applied polyester reinforced solvent-free. KEMPEROL 2K-PUR Speedshot combined with KEMPEROL 2K-PUR is the ideal solution for all applications where speed is essential. These include balconies. KEMPEROL® 2K-PUR is a solvent-free and odourless, fully reinforced, polyurethane resin-based liquid waterproofing system. It is ideal for use on sustainablility.

Author: Tuzahn Tojazshura
Country: Tanzania
Language: English (Spanish)
Genre: Health and Food
Published (Last): 7 August 2009
Pages: 307
PDF File Size: 1.72 Mb
ePub File Size: 3.86 Mb
ISBN: 696-2-32894-748-3
Downloads: 24398
Price: Free* [*Free Regsitration Required]
Uploader: Kigak

Please consult Kemper System Limited for specific substrate guidance.

Ejot Srbija -specijalista u tehnologiji povezivanja. KEMPEROL 2K PUR

Pour primer Component B into Component A and mix for approximately 2 minutes with a clean spiral agitator on slow speed without creating any bubbles or streaks. Each product clause is authored in NBS format and is intended for inclusion in project specifications. Use only proprietary membrane resins and materials, as supplied by the membrane manufacturer. Kemperol Mixing Sand 00 35 0.

Kemperol 2K-PUR

When ambient temperatures are at or expected to fall below 50 degrees F 10 degrees Cor reach 85 degrees F 30 degrees C or higher, follow Membrane System Manufacturer’s recommendations for weather related additives and application procedures. Kemperol Surfacing Sand 0 18 0. Do not proceed with the work until test results and workmanship are approved by Architect.

Granule-surfaced membrane shall have all loose granules removed from the surface by vacuuming and power brooming. Apply coating at the manufacturer’s recommended application rate. Fabric must be left intact at these holes to prevent intrusion of soil, kemperool, sand, or concrete into the kempedol core.

  NETAPP BASIC CONCEPTS QUICKSTART GUIDE PDF

Note that all insulation requires cover board. Schedule tests promptly to allow timely installation of protection layers.

Kemperol 2K-PUR – Kemper System Ltd

Fit plywood to all penetrations, projections, and nailers. Substrates shall be inspected and repaired as needed to provide a proper surface to receive waterproofing system. Note that traffic surfacing is not suitable for flashings. After 48 hours at 73 degrees F, 50 percent relative humidity with rubber pneumatic tires.

Delete if not applicable. Application of waterproofing membrane may proceed while air temperature is between 22k degrees F 5 degrees C and 90 degrees F 30 degrees C providing the substrate is a minimum of 5 degrees F above the dew point.

Kemper System Ltd Web: Determine the locations for the horizontal surfacing profile joints and mark off with a line. A technical consultant from will be in touch soon. Field Quality Control Tests of completed sections of waterproofing membrane shall be successfully completed before proceeding with protection layers and overburden.

Kemperol 2K-PUR highly permeable roofing membrane

A 2-component polyurethane-based product, it forms a permanently elastic, seamless, yet highly permeable membrane that is both durable and tear-resistant.

Supports for electrical conduit and gas lines 1 inch or less in diameter, and bases for lightning protection rods and cable, can be adhered directly to the membrane surface with a single-component, polyurethane construction adhesive.

If movement is necessary, provide complete protection of affected areas. Hollow-core panels, T-panels, and Twin-T panels shall have grouted joints between panels and shall be provided with mechanical securement from panel to panel. Maintain mock-up for quality control during the progress of the remaining work. Two-component, solvent-free epoxy resin tile adhesive for improved adhesion and freeze-thaw resistance, as per ANSI A Secondary products that are required shall be as recommended and approved in writing by the waterproofing system manufacturer.

  KUSHYAR IBN LABBAN PDF

Edges shall be checked so that no edges are left substantially unsupported along the flutes. Solid to walk on: Cracked, broken or otherwise damaged overburden materials must be removed and discarded. Provide primers and other secondary materials that are produced or are specifically recommended by manufacturer of membrane waterproofing system to ensure compatibility.

Adhering to gypsum-based panels, cementitious stucco, synthetic stucco, wood or metal siding, and other similar materials is not acceptable.

Not suitable for insulated assembly. Allow the aggregate-filled surfacing to cure for approximately 4 hours, then remove excess aggregate by brooming and vacuuming. Spalls and other deterioration shall be repaired in accordance with the requirements of the Architect and Membrane manufacturer. Overlap fabric in direction of water flow.

Mechanically attach insulation and cover board using fastener manufacturers’ recommendations for the appropriate fastener and plate type, size and length. Securement to gypsum-based panels, cementitious stucco, synthetic stucco, wood or metal siding or coping, and other similar materials is not acceptable. Install a strainer basket to prevent debris from clogging the drainage line.

Flood test shall be of a 24 hour minimum duration, and shall apply a 2 inch water head of over the entire application put.