Simodrive 6RA27 LIVE PLC Questions And Answers. Join Date: Nov Location: UK. Posts: 5, Here’s what one of the manuals says. List of ebooks and manuels about Simodrive 6ra27 manual – DC- Servo Simodrive 6RADV Siemens 6RA27 90 Amp DC Drive Beg. On CNC-Shopping Intl website, Buy online SIEMENS SIMODRIVE 6RA Simoreg Spindle drive control board or complete drive. Find SIEMENS SIMOREG 6RA.

Author: Gahn Kezilkree
Country: Guinea
Language: English (Spanish)
Genre: Literature
Published (Last): 19 June 2011
Pages: 448
PDF File Size: 19.80 Mb
ePub File Size: 10.50 Mb
ISBN: 694-5-67828-157-2
Downloads: 4711
Price: Free* [*Free Regsitration Required]
Uploader: Kill

So field reversal makes operation in all four quadrants possible. Line-side overvoltage protection 7VV Besides the CCP, implementation of a high-speed DC circuit-breaker is the only way of protecting the converter against the effects of conduction-through.

When braking with field reversal on 1Q devices, a fuse must be implemented in the direct current circuit like for 4Q devices for type see comparable 4Q device. Please refer to the circuit diagrams of the power section in the Operating Instructions; Section 6. When making the measurement, you must wait approx. Depending on the setting for P, the output of the speed controller indicates the torque setpoint or the current setpoint.

Simodrive 6ra27 – eBook and Manual Free download

Check the motor for sparkfree commutation of the current. Setting parameter P with manuaal factory setting of 0, or for indexed parameters, the value under “FS”.

Perform trace recording and evaluate Trace 1 and Trace 2. Older systems being retrofitted frequently have a high-speed DC circuit-breaker.

The status of terminal 36 nanual mapped in 66ra27 B and the inverted signal of it in B B for terminal Output field current control loop firing angle, fieldSheet G Documents Flashcards Grammar checker. Phase control of the AC input voltage with suitable assignment of the thyristors to be fired is performed in such a way that a variable direct voltage occurs at the output, see below. You will find the item number of the module in the screen print on the module, it is CA Temporarily only parameterize control via terminals: You have the option to buy a product that is much cheaper than the new or 6fa27 version of the product and save money while benefitting from a product that is worthy of the quality of the Cnc-Shopping Intl.

  CODIGO INTERNACIONAL DE NOMENCLATURA BOTANICA PDF

Step reponse for discontinous current, e. When applying the supply voltage manial the electronics supply, the ON command must not be set until the device is initialized lasts approx. Higher value of the setpoint step change P Lower rates of current change are permissible on old motors than on modern DC motors.

SIMOREG K 6RA23 Instruction Manual

Circulating-current-free 6rz27 that the current must be reduced to zero in the one current direction before the opposite current direction is enabled. Failure to follow the relevant Operating Instructions may result in death, serious injury or considerable material damage.

Operation of a permanent-magnet DC motor, e. After the bearing useful life has elapsed, these bearings, too, must be replaced. F cannot be acknowleged until the cause of the original fault message that triggered F is eliminated.

If a fault message occurs, binary output terminal 46 has a low signal. Settings for speed-dependent current limiting, see Section 9. Stabilizing series windings are frequently to be found in old motors.

Inverter stability limit Alpha W: The fault number is transferred in the high byte of connector K as long as this fault message has not been acknowledged 6ra227 is therefore still displayed on the PMU with Fxxx ; the alarm number is transferred in the low byte of K The source from which controlling is mnaual is parameterized in P The operating status of the device: Check the current load current with r and measure with an ammeter, any deviations may point to a fault in 6RA Approximation of the absolute value of the frequency response to the optimum value mmanual is performed for the largest possible frequency range.

After elimination of the cause of the fault, the fault must be acknowledged, then OFF1 must be set in order to return to operating state o7. Define ON signal via terminal 37 manuual operating enable via terminal When the current limit is reached, check P, P, observe permissible limit values for the motor when making settings. The current limits have no affect in controlled operation, only the set firing angle limits for Alpha G and Alpha W have an effect.

  COMPUTER NETWORKS AND INTERNETS COMER PDF

Your cart is empty. Profibus, the time monitoring 6a27 the bus signal must be activated for Profibus: Manuxl of the firing pulses Pulse during operation: Current controller precontrol is active at the same time.

For the connector – binector list see Chapter 12 of the Operating Instructions. The rated device field current r Then voltage must be applied to power section; otherwise F will occur.

U-Last Motor Laststrom Motor armature voltage Load current Idc in [A] U in [V] 50 0 0 2 4 6 8 10 0 0 2 4 6 8 10 6 8 10 in [ms] Time inZeit[ms] in [ms] Time inZeit [ms] Discontinous current, half rated motor speed, without smoothing reactor U-Last Motor Laststrom Load current 90 6fa27 70 60 Idc in [A] U in [V] Motor armature voltage 40 30 20 50 10 0 0 50 2 4 6 8 10 0 0 in [ms] Time in Zeit [ms]: A diesel generator cannot absorb regenerative current.

The number of the connector whose value is to be output via terminal 14 is entered in parameter P, e. Products that are new, refurbished, used or for standard manuaal service have been fully cleaned, checked and tested via simulators or test rigs when available by our skilled technicians prior to their sale.

As a result of this necessary reduction of the field current, a delay time up until the torque direction switches over occurs as a result of the time constant of the field current reduction. If control is performed via bus only, e.